Borehole Pumps
Once the water level is more than 8 metres below the pump, no surface pump will lift: you need a submersible. Lowered into the well or borehole, it stays primed, quiet and frost-protected. The casing diameter decides the model.
No products currently match this selection.
Read the full guide
Borehole pumps: when they are the only option
A borehole pump is lowered into the water, to the bottom of the well or borehole, and lifts to the surface. It becomes essential as soon as the water level sits more than 8 metres below the pump: at that depth no surface pump can lift at all, whatever its power.
Submerged, the pump is also quiet, protected from frost and always primed. In exchange, installation calls for more care: a watertight cable, a safety rope, a suitable rising main and protection against dry running.
Well, borehole or tank: three situations
| Situation | Typical diameter | What matters |
|---|---|---|
| Traditional wide well | Ø unrestricted | Depth and discharge height |
| 3″ or 4″ borehole | 75 to 100 mm | Outside diameter of the pump, non-negotiable |
| Tank or reservoir | — | Draw-off rate and level control |
In a borehole, diameter overrides everything else: a 4-inch pump will not go down a 3-inch casing. Measure the internal diameter of the casing before anything else.
Sizing: flow, total head, dynamic water level
The key figure is the dynamic water level — the level once pumping has started, not the level at rest. In a borehole the gap between the two is often several metres. Total head adds that dynamic level, the height to the outlet and the friction losses in the rising main.
- Working flow in m³/h, and the flow the borehole can actually sustain without emptying.
- Installation depth and dynamic level measured while pumping.
- Casing diameter and the cable length required.
- Water quality: sand content, aggressiveness, brackish water.
- Supply: 230 V single-phase or 380–400 V three-phase, and cable cross-section over the run.
A borehole that yields less than the pump delivers will empty: the pump runs dry and destroys itself. It is the most common mistake, and the most expensive.
Electric or solar submersible?
On a site connected to the grid, an electric borehole pump gives constant flow, day and night. On an isolated plot with no meter, the solar version avoids connection charges: see our solar water pumps. The hydraulic sizing, however, is identical in both cases.
With a booster set for the house
A borehole pump on its own does not regulate pressure. To supply a dwelling it is paired with a diaphragm vessel and pressure switch, or with a booster set, to avoid constant starting and give steady pressure at the tap.
Frequently asked questions
At what depth is a borehole pump needed?
As soon as the water level while running is more than about 8 metres below the pump. If it stays within 8 metres, a surface self-priming pump is enough.
What is the difference between a well and a borehole?
A well is wide and shallow; a borehole is a narrow casing, often 3 or 4 inches, going much deeper. A borehole dictates a precise pump diameter.
How do I protect the pump from dry running?
With a level probe, a float switch or a control box with low-water protection. On a borehole of limited yield it is essential.
Will a borehole pump tolerate sandy water?
It tolerates a limited sand content, stated by the manufacturer. Above that you need a purpose-built pump, or wear becomes very rapid.
Is a non-return valve needed?
Yes, to stop the water column falling back at every shutdown and spinning the pump backwards.
What cable cross-section should I allow?
It depends on the power and the total run. Too small a section causes voltage drop, motor heating and nuisance tripping.