Description
Solar pool pump 1,200 W – 27 m³/h, 72 V DC — A solar-powered swimming pool pump for circulating clean pool water through your existing filter, with a brushless DC motor and a visible pre-filter. It operates from a correctly sized PV array during suitable daylight hours. The headline 27 m³/h is the maximum flow at very low head; 19 m is the maximum head at zero flow. They are separate end points of the performance curve.
Why choose this version?
High-flow filtration with a 72 V motor
For a pool around 70 m³, four hours calls for 17.5 m³/h at the filter. The redrawn curve suggests around 18 m³/h at 8 m head. Size the filter and pipework for that operating flow and the pump’s 3″ connections.
This 27 m³/h version uses a 90–120 V solar input, with cold-weather array Voc strictly below 150 V. Three suitable 500 W modules in series illustrate the 1,500 W minimum; verify the actual module data and site temperature.
Pool circulation
The clear-lid pre-filter can be inspected and cleaned before debris reaches the pump. Size your sand or cartridge filter for the operating flow.
Solar generation
The panel count is an example of the required array power. A wattage alone never proves electrical compatibility.
Hydraulics
Match the 3″ / 3″ connections and the actual flow to pipes, valves, filter and any heater or chlorinator.
Technical specifications
| Brand | Flocea |
|---|---|
| Supply mode | Direct solar DC |
| Motor power | 1,200 W |
| Maximum flow | 27 m³/h at very low head |
| Maximum total head | 19 m at zero flow |
| Inlet / outlet | 3″ / 3″ |
| Motor nominal voltage | 72 V DC |
| PV input operating range | 90–120 V DC |
| Mains input | No AC input on this version |
| Minimum PV array power | ≥ 1,500 Wp |
| Maximum array open-circuit voltage | Below 150 V at the site’s lowest temperature |
| Pump cable in catalogue | 2 m |
| Indicative flow at 8 m head | About 18 m³/h, indicative curve reading |

Performance curve: flow changes with head
The supplied catalogue curve has been redrawn for this hydraulic family. Pump flow falls when the filtration circuit adds resistance. The highlighted point at 8 m of total dynamic head is a graphical approximation, not a guaranteed flow rate for your pool.

Which pool volume can this pump serve?
A useful starting point is to circulate the pool volume in 4–6 hours: divide the volume by the chosen period to find the target flow through the filter. For a 70 m³ pool and four hours, the target is 17.5 m³/h at the filter. At 8 m head, this model’s approximate curve reading is 18 m³/h under favourable conditions.
| Catalogue maximum at almost no head | 27 m³/h; this is not the flow through your filter. |
|---|---|
| Indicative point at 8 m head | Approximately 18 m³/h; verify on the installation. |
| Theoretical circulation in 4 hours | About 72 m³ at that operating point. |
| Theoretical circulation in 6 hours | About 108 m³ at that operating point. |
This table is a preliminary sizing aid, not a guarantee of daily filtration. Check the rated flow of the filter, skimmers, heater and chlorinator. A solar-only pump cannot be assumed to receive four hours of full sunshine every day.
Solar panels and electrical supply
Minimum array rating: at least 1,500 Wp. One practical power example is 3 × 500 W panels in series. Confirm the actual module data sheets: combined Vmp must suit the 90–120 V input during operation, combined Voc corrected for the coldest local conditions must stay strictly below 150 V, and module current must suit the supplied controller. Panels with the same watt rating may have very different voltages.
This is the solar-only version, with a 72 V DC motor nominal voltage and no direct mains AC input. Without sufficient sunlight, the circulation rate can fall or the pump can stop. It is not a standard 230 V pool pump.
How the solar-pool system connects

Plan the filtration circuit
- Measure pool volume, target run time, pipe diameter, filter rating and actual head losses; locate the operating point on the curve.
- Position the surface pump on a stable base close to the suction line. Keep access to the clear pre-filter lid for cleaning and prime according to the supplied instructions.
- Connect the pump to the filter and return line in the proper flow direction. Do not exceed the filter’s rated flow or presume a specific self-priming lift that is not documented on the French listing.
- Have the PV array, DC isolator and protection, controller and any mains input installed according to the supplied manuals. Measure the actual flow through the filter after commissioning.
Questions before ordering
Will it deliver 27 m³/h through my filter?
No fixed filter flow can be promised from Qmax. At an illustrative 8 m total head the curve suggests around 18 m³/h; your pipework, filter and sunlight change the operating point.
What pool size is this model for?
A preliminary 70–110 m³ at the 8 m-head example and 4–6 hours of theoretical turnover. Confirm the actual filter flow and available operating hours.
How many solar panels are required?
At least 1,500 Wp is specified. 3 × 500 W panels in series illustrates the wattage, subject to Vmp, cold-weather Voc and controller-current checks. Panels are sold separately.
What comes with the pump?
The Flocea pump and the matching solar DC controller are included. Solar panels are sold separately; other installation parts depend on your site.
Can I keep my current pool filter?
Only if its rated flow, pipe connections and any associated equipment match the pump’s real operating flow. An undersized filter can create excessive pressure losses.
Is this pump self-priming?
The existing French listing does not specify a certified self-priming lift. Follow the supplied priming instructions and confirm the installation height before ordering.
Can the solar-only version run at night?
Not from PV panels alone. This version has no mains AC input and its daytime output follows available sunshine.
Can I plug it directly into a balcony solar system?
A conventional microinverter AC output is not the DC PV input. The solar-only version requires a matching DC array and controller. On the hybrid version, mains wiring and the dedicated PV input must be assessed separately.

Controller user manual
Panel and pump connection, control panel, operating modes, fault codes and settings: the English manual for the DC solar controller of your pump.
- Choosing and wiring the panels
- Operation and protections
- Fault codes and settings
Low-voltage controllers for DC solar pumps from 24 V to 110 V.