Solar pool pump 500 W – 15 m³/h, 48 V DC

€499.00 incl. VAT

Solar pool pump 500 W – 15 m³/h, 48 V DC · Maximum 15 m³/h, 14 m head, 2″ / 2″ ports. Approx. 8 m³/h at 8 m head; indicative pool 30–50 m³ for 4–6 h turnover.Matching solar DC controller included; panels sold separately. PV ≥ 750 Wp, e.g. 2 × 450–500 W panels in series, subject to electrical checks.

Available on back-order

Cover of the Flocea manual for the low-voltage solar controller for DC pumps

16 pages · PDF · 2.4 MB

Solar controller manual

Secure payment by card, PayPal, Apple Pay or Google Pay.

Well-documented choice
Clearly detailed specifications

Tailored response
Configuration matched to your site

Tracked delivery
Arranged to suit the project

Flocea support
A named point of contact

SKU: FLO-PSP-DC-500-15
Category:
Brands:

Description

Solar pool pump 500 W – 15 m³/h, 48 V DC — A solar-powered swimming pool pump for circulating clean pool water through your existing filter, with a brushless DC motor and a visible pre-filter. It operates from a correctly sized PV array during suitable daylight hours. The headline 15 m³/h is the maximum flow at very low head; 14 m is the maximum head at zero flow. They are separate end points of the performance curve.

15 m³/hMaximum flow
14 mMaximum total head
500 WBrushless motor
2″ / 2″Inlet / outlet
The Flocea pump and its matching solar DC controller are included. Solar panels are sold separately. Select the remaining cables, DC protection, mounting and pipework for the actual installation.
Indicative pool size: 30–50 m³ if total head is close to 8 m, with approximately 8 m³/h available for a theoretical 4–6 hour turnover. Filter losses, pipework and actual daylight can change the outcome.

Why choose this version?

Solar circulation for a smaller or above-ground pool

For a pool around 30 m³, a four-hour turnover would call for 7.5 m³/h through the filter. The catalogue curve suggests about 8 m³/h at an illustrative 8 m head in favourable sun. The filter and pipework must be checked before choosing this compact model.

Two suitable 450–500 W panels in series are a power example above the 750 W minimum. Their combined operating and cold-weather open-circuit voltages still have to suit this particular 60–90 V controller.

Pool circulation

The clear-lid pre-filter can be inspected and cleaned before debris reaches the pump. Size your sand or cartridge filter for the operating flow.

Solar generation

The panel count is an example of the required array power. A wattage alone never proves electrical compatibility.

Hydraulics

Match the 2″ / 2″ connections and the actual flow to pipes, valves, filter and any heater or chlorinator.

Technical specifications

Brand Flocea
Supply mode Direct solar DC
Motor power 500 W
Maximum flow 15 m³/h at very low head
Maximum total head 14 m at zero flow
Inlet / outlet 2″ / 2″
Motor nominal voltage 48 V DC
PV input operating range 60–90 V DC
Mains input No AC input on this version
Minimum PV array power ≥ 750 Wp
Maximum array open-circuit voltage Below 100 V at the site’s lowest temperature
Pump cable in catalogue 2 m
Indicative flow at 8 m head About 8 m³/h, indicative curve reading
Flocea 500 W pool pump specifications: 15 m³/h, 14 m head, 2″ / 2″ connections

Performance curve: flow changes with head

The supplied catalogue curve has been redrawn for this hydraulic family. Pump flow falls when the filtration circuit adds resistance. The highlighted point at 8 m of total dynamic head is a graphical approximation, not a guaranteed flow rate for your pool.

Flocea 500 W pool pump curve: approximately 8 m³/h at 8 m of total head
Redrawn from the supplied catalogue. Intermediate points are indicative; detailed test conditions were not provided.

Which pool volume can this pump serve?

A useful starting point is to circulate the pool volume in 4–6 hours: divide the volume by the chosen period to find the target flow through the filter. For a 30 m³ pool and four hours, the target is 7.5 m³/h at the filter. At 8 m head, this model’s approximate curve reading is 8 m³/h under favourable conditions.

Catalogue maximum at almost no head 15 m³/h; this is not the flow through your filter.
Indicative point at 8 m head Approximately 8 m³/h; verify on the installation.
Theoretical circulation in 4 hours About 32 m³ at that operating point.
Theoretical circulation in 6 hours About 48 m³ at that operating point.

This table is a preliminary sizing aid, not a guarantee of daily filtration. Check the rated flow of the filter, skimmers, heater and chlorinator. A solar-only pump cannot be assumed to receive four hours of full sunshine every day.

Solar panels and electrical supply

Minimum array rating: at least 750 Wp. One practical power example is 2 × 450–500 W panels in series. Confirm the actual module data sheets: combined Vmp must suit the 60–90 V input during operation, combined Voc corrected for the coldest local conditions must stay strictly below 100 V, and module current must suit the supplied controller. Panels with the same watt rating may have very different voltages.

This is the solar-only version, with a 48 V DC motor nominal voltage and no direct mains AC input. Without sufficient sunlight, the circulation rate can fall or the pump can stop. It is not a standard 230 V pool pump.

How the solar-pool system connects

Flocea Solar only wiring concept with 2 × 450–500 W panels in series, controller, pump, filter and pool
Functional concept only: the supplied controller manual and a qualified installer determine terminal positions, protection and settings.
Before wiring, check hot-weather Vmp, cold-weather Voc and Imp/Isc of the chosen panels, plus the controller input-current limit. The illustrated panel count is a power example, not a universally compatible kit.

Plan the filtration circuit

  1. Measure pool volume, target run time, pipe diameter, filter rating and actual head losses; locate the operating point on the curve.
  2. Position the surface pump on a stable base close to the suction line. Keep access to the clear pre-filter lid for cleaning and prime according to the supplied instructions.
  3. Connect the pump to the filter and return line in the proper flow direction. Do not exceed the filter’s rated flow or presume a specific self-priming lift that is not documented on the French listing.
  4. Have the PV array, DC isolator and protection, controller and any mains input installed according to the supplied manuals. Measure the actual flow through the filter after commissioning.

Questions before ordering

Will it deliver 15 m³/h through my filter?

No fixed filter flow can be promised from Qmax. At an illustrative 8 m total head the curve suggests around 8 m³/h; your pipework, filter and sunlight change the operating point.

What pool size is this model for?

A preliminary 30–50 m³ at the 8 m-head example and 4–6 hours of theoretical turnover. Confirm the actual filter flow and available operating hours.

How many solar panels are required?

At least 750 Wp is specified. 2 × 450–500 W panels in series illustrates the wattage, subject to Vmp, cold-weather Voc and controller-current checks. Panels are sold separately.

What comes with the pump?

The Flocea pump and the matching solar DC controller are included. Solar panels are sold separately; other installation parts depend on your site.

Can I keep my current pool filter?

Only if its rated flow, pipe connections and any associated equipment match the pump’s real operating flow. An undersized filter can create excessive pressure losses.

Is this pump self-priming?

The existing French listing does not specify a certified self-priming lift. Follow the supplied priming instructions and confirm the installation height before ordering.

Can the solar-only version run at night?

Not from PV panels alone. This version has no mains AC input and its daytime output follows available sunshine.

Can I plug it directly into a balcony solar system?

A conventional microinverter AC output is not the DC PV input. The solar-only version requires a matching DC array and controller. On the hybrid version, mains wiring and the dedicated PV input must be assessed separately.

Cover of the Flocea manual for the low-voltage solar controller for DC pumps

16 pages · PDF · 2.4 MB

Controller user manual

Panel and pump connection, control panel, operating modes, fault codes and settings: the English manual for the DC solar controller of your pump.

  • Choosing and wiring the panels
  • Operation and protections
  • Fault codes and settings
Open the PDF manual

Low-voltage controllers for DC solar pumps from 24 V to 110 V.

Additional information

Supply mode

Direct solar DC

Motor power

500 W

Maximum flow

15 m³/h at very low head

Maximum total head

14 m at zero flow

Inlet / outlet

2″ / 2″

PV input operating range

60–90 V DC

Minimum PV array power

≥ 750 Wp

Solar pump configurator