Description
What is included in your purchase
The pump, the MPPT controller and its accessories are included. Solar panels, pipes and DC protection are sold separately.
Very large volumes to move over a low head? The Flocea 1,500 W solar surface pump is the Flocea surface pump with the highest flow: up to 55 m³/h with 3-inch connections. Its brushless DC motor and MPPT controller run directly on the energy of 4 photovoltaic panels: no battery, no generator, no electricity bill.
What is it for?
Furrow and flood irrigation
Supply a canal, furrows or a head-of-field basin with a high flow.
Basin-to-basin transfer
Quickly empty or fill a farm pond, a lake or a large clear-water reservoir.
Water renewal
Circulate large volumes of water in a pond or a farm basin with the sun.
The pump stands out of the water, as close to the source as possible and as little as possible above the water level. The 17 m head is not a suction depth: for deep water you need a submersible pump. It is designed for clear water: a strainer is essential, and water loaded with sand, mud or fibres wears it out prematurely.

Specifications of the Flocea 55 m³/h pump
| Brand | Flocea |
|---|---|
| Type | Solar centrifugal surface pump, clear water |
| Motor | Brushless DC, 1,500 W; rated voltage 110 V |
| Maximum flow | 55 m³/h = 55,000 L/h = 917 L/min, at very low head |
| Maximum head | 17 m, at zero flow |
| Inlet / outlet | 3″ / 3″ (DN80); check the thread type for fittings |
| Controller | MPPT for direct current (DC), included |
| MPPT voltage range | 110–150 V DC |
| PV array open-circuit voltage | Strictly below 200 V, cold correction included |
| Minimum PV power | 2,000 Wp |
| Indicative set-up | 4 × 500 Wp in series = 2,000 Wp |
| Cable | 2 m |
| Reference | FLO-SCPM55-17-110-1500 |

Work out the total head of your installation
Before comparing flow rates, estimate the total head the pump will have to deliver. Two measurements are enough.

Total head ≈ H + 10% × L
- H: height difference between the (lowest) water level and the outlet.
- L: pipe length to the outlet; the 10% covers friction losses.
- Pressure needed at the outlet (sprinkler, drip line): add 10 m per bar.
Example: tank 8 m above the water level, 50 m of pipe → total head ≈ 8 + 5 = 13 m. With 1 bar needed at the outlet: 13 + 10 = 23 m.
Then go by the flow the pump delivers at that total head, not its maximum flow. Full 3-step method and how to read the curve.
Water more than 7–8 m below the pump? See our solar submersible pumps.
Filling a reserve? See our flexible water tanks · Have my installation sized
What flow at your head?
Flow decreases as the total dynamic head (TDH) increases. It adds up the suction lift, the elevation to the delivery point, the friction losses in the pipes and the pressure required at the outlet. At high flows the pipes often decide: a pipe that is too small adds several metres of head.
Example: at 8 m head, expect about 36 m³/h in full sun; at 14 m, about 16 m³/h. The table and curve below give the other duty points.
| Head | Indicative flow in full sun |
|---|---|
| 4 m | ≈ 46.2 m³/h |
| 6 m | ≈ 41.5 m³/h |
| 8 m | ≈ 36 m³/h |
| 10 m | ≈ 30.5 m³/h |
| 12 m | ≈ 23.8 m³/h |
| 14 m | ≈ 16 m³/h |

4 panels in series: the recommended set-up
The controller works between 110 and 150 V and accepts no more than 200 V open circuit. The simplest set-up: 4 identical panels of about 500 Wp connected in series, i.e. 2,000 Wp, the recommended minimum. In series, voltages add up and the current stays that of one panel. Check these values on the label of each panel:
| Power (Pmax) | 500 to 550 Wp per panel |
|---|---|
| Maximum power voltage (Vmp) | 28 to 37 V: in series, 112 to 148 V |
| Open-circuit voltage (Voc) | 45 V maximum per panel: in series ≤ 180 V, about 199 V at −10 °C |
| Number of panels | 4 in series, never more |
Connecting the MPPT controller
Panels → P+ / P−
The PV array connects to the solar input P+ and P−, with correct polarity and suitable DC protection.
Motor → U / V / W
The three motor phase conductors connect to the U, V and W outputs of the controller.
Level sensors → dedicated inputs
Compatible probes can stop the pump when the source runs dry or the tank is full. Terminals and logic are checked in the manual.

Principle diagram, to be completed with the manual of the equipment supplied. Wire with the power off, by a qualified person, then check polarity and voltage before commissioning.
The full Flocea range of solar surface pumps
High-pressure models for low flows and high heads, centrifugal models for large flows: choose according to your needs.
| Pump | Max. flow | Max. head | Connections | Panels |
|---|---|---|---|---|
| 210 W solar pump – 2 m³/h | 2 m³/h | 25 m | 1″ | 1 × ~400 Wp |
| 280 W solar pump – 2 m³/h | 2 m³/h | 30 m | 1″ | 1 × ~400 Wp |
| 550 W solar pump – 3 m³/h | 3 m³/h | 50 m | 1″ | 2 × ~450 Wp |
| 750 W solar pump – 3 m³/h | 3 m³/h | 65 m | 1″ | 3 × ~450 Wp |
| 550 W solar pump – 6 m³/h | 6 m³/h | 30 m | 1″ | 2 × ~400 Wp |
| 550 W solar pump – 18 m³/h | 18 m³/h | 14 m | 2″ | 2 × ~400 Wp |
| 750 W solar pump – 21 m³/h | 21 m³/h | 14 m | 2″ | 3 × ~450 Wp |
| 1,100 W solar pump – 26 m³/h | 26 m³/h | 15 m | 2″ | 3 × ~500 Wp |
| 1,500 W solar pump – 27 m³/h | 27 m³/h | 21 m | 2″ | 4 × ~500 Wp |
| 1,500 W solar pump – 55 m³/h (this page) | 55 m³/h | 17 m | 3″ | 4 × ~500 Wp |
Preparing an installation that keeps the flow
- Place the pump on a stable, dry base, out of the water, protected from frost and as close to the source as possible.
- Plan a short, airtight and non-collapsible suction line, at least 3″, with a strainer and foot valve.
- Keep the strainer submerged and away from the bottom to limit debris intake.
- Fill the pump casing and suction line with water before each start from empty; never run the pump dry.
- Size the delivery line according to length and flow: a PE pipe of at least 90 mm, 110 mm or more as soon as the line exceeds about a hundred metres.
- Mount the controller in the shade, connect panels, pump and probes with a DC isolator, then check fittings and strainer regularly.
Your questions about this solar pump
Does the pump deliver 55 m³/h all the time?
No. 55 m³/h is a maximum flow, at very low head and in full sun. At 8 m head, expect about 36 m³/h. Head, friction losses and sunlight determine the actual flow.
Can it lift water from a deep well?
No. It is a surface pump: it only draws water up a few metres and must be placed close to the water level. The 17 m head is not a suction depth. For a well or borehole, choose a submersible pump.
Which solar panels should I choose?
4 identical panels of 500 to 550 Wp in series: Vmp 28 to 37 V and Voc of 45 V maximum each. Avoid panels of 580 Wp and more, whose open-circuit voltage is too high.
Does it work at night or in cloudy weather?
In direct solar mode it runs only when there is enough PV energy. Clouds reduce or interrupt the flow; at night, use the water stored in a reservoir.
What pipe diameter do I need?
The ports are 3 inches. For the delivery line, plan a PE pipe of at least 90 mm, 110 mm or more as soon as the line exceeds about a hundred metres. A pipe that is too small adds friction losses and reduces the flow.
Can it pump dirty water?
It is designed for clear water. A strainer is essential; sand, mud or fibres wear the impeller and can block the pump.
Are level sensors mandatory?
No, but they are recommended: they stop the pump when the source runs dry or the reservoir is full. Their connection is checked in the controller manual.
Let’s start from your water needs
Tell us the daily volume you need, the water level at the source, the elevation, the length and diameter of the pipes and the model of your panels: we check the right pump and set-up before you order.