1,100 W solar surface pump – 26 m³/h, 15 m head

€749.00 incl. VAT

Indicative lead time: 3 to 4 weeks

High-flow solar surface pump for irrigation, reservoir filling and clear-water transfer, with no grid connection. Maximum flow 26 m³/h, maximum head 15 m, 1,100 W brushless DC motor (72 V) and 90–120 V MPPT controller included. Inlet and outlet: 2 inches (DN50).Recommended supply: 3 identical panels of about 500 Wp in series, i.e. 1,500 Wp, after checking their voltages. Minimum solar power: 1,500 Wp.Solar panels sold separately. Actual flow depends on head and sunlight.

Available on back-order

  • Indicative lead time: 3 to 4 weeksAfter your order.
  • Free deliveryMainland France and Europe.
  • Secure paymentCard, PayPal, Apple Pay or Google Pay.
  • Any questions?Contact Flocea before ordering.
SKU: FLO-SCPM26-15-72-1100
Category: ,

Description

What is included in your purchase

The pump, the MPPT controller and its accessories are included. Solar panels, pipes and DC protection are sold separately.

Several hectares to water, large reservoirs to fill? The Flocea 1,100 W solar surface pump is built to deliver more than 20 m³/h as long as the head stays moderate. Its brushless DC motor and MPPT controller run directly on the energy of 3 photovoltaic panels: no battery, no generator, no electricity bill.

26 m³/hmaximum flow
15 mmaximum head
1,100 W72 V brushless motor
2″ / 2″inlet / outlet
The right flow at the right head. 26 m³/h and 15 m are two separate maximums: at 8 m head the pump delivers about 15.8 m³/h in full sun. Useful flow depends on elevation, pipework, required pressure and sunlight.

What is it for?

Farm irrigation

Supply a larger irrigation network, sector by sector, with the sun.

Large reservoirs and ponds

Fill a flexible tank of several tens of cubic metres or a farm pond in one sunny day.

Market gardens and orchards

Refill every day the reservoir that then feeds the drip system, with its filtration and regulation.

The pump stands out of the water, as close to the source as possible and as little as possible above the water level. The 15 m head is not a suction depth: for deep water you need a submersible pump. It is designed for clear water: a strainer is essential, and water loaded with sand, mud or fibres wears it out prematurely.

Flocea 1,100 W solar surface pump beside an irrigation canal in an orchard, with a lay-flat delivery hose and 3 solar panels
Installation illustration: pump and MPPT controller included; 3 panels, mounts and pipes sold separately.

Specifications of the Flocea 26 m³/h pump

Brand Flocea
Type Solar centrifugal surface pump, clear water
Motor Brushless DC, 1,100 W; rated voltage 72 V
Maximum flow 26 m³/h = 26,000 L/h = 433 L/min, at very low head
Maximum head 15 m, at zero flow
Inlet / outlet 2″ / 2″ (DN50); check the thread type for fittings
Controller MPPT for direct current (DC), included
MPPT voltage range 90–120 V DC
PV array open-circuit voltage Strictly below 150 V, cold correction included
Minimum PV power 1,500 Wp
Indicative set-up 3 × 500 Wp in series = 1,500 Wp
Cable 2 m
Reference FLO-SCPM26-15-72-1100
Specifications of the Flocea 1,100 W solar surface pump: 26 m³/h, 15 m head, 2-inch connections

Work out the total head of your installation

Before comparing flow rates, estimate the total head the pump will have to deliver. Two measurements are enough.

Diagram: working out the total head of a solar surface pump. H is the height difference between the water level and the outlet into the tank, L the pipe length; total head ≈ H + 10% × L, plus 10 m per bar of pressure needed at the outlet.
Measure the height difference H and the pipe length L, then apply the formula.

Total head ≈ H + 10% × L

  • H: height difference between the (lowest) water level and the outlet.
  • L: pipe length to the outlet; the 10% covers friction losses.
  • Pressure needed at the outlet (sprinkler, drip line): add 10 m per bar.

Example: tank 8 m above the water level, 50 m of pipe → total head ≈ 8 + 5 = 13 m. With 1 bar needed at the outlet: 13 + 10 = 23 m.

Then go by the flow the pump delivers at that total head, not its maximum flow. Full 3-step method and how to read the curve.

Water more than 7–8 m below the pump? See our solar submersible pumps.

What flow at your head?

Flow decreases as the total dynamic head (TDH) increases. It adds up the suction lift, the elevation to the delivery point, the friction losses in the pipes and the pressure required at the outlet. At high flows the pipes often decide: a pipe that is too small adds several metres of head.

Example: at 8 m head, expect about 15.8 m³/h in full sun; at 12 m, about 9.3 m³/h. The table and curve below give the other duty points.

Head Indicative flow in full sun
4 m ≈ 21.3 m³/h
6 m ≈ 18.6 m³/h
8 m ≈ 15.8 m³/h
10 m ≈ 12.7 m³/h
12 m ≈ 9.3 m³/h
Flow–head curve of the Flocea 1,100 W, 26 m³/h solar surface pump
Indicative flow according to head, in full sun with the recommended PV power. Flow decreases when sunlight drops.

3 panels in series: the recommended set-up

The controller works between 90 and 120 V and accepts no more than 150 V open circuit. The simplest set-up: 3 identical panels of about 500 Wp connected in series, i.e. 1,500 Wp, the recommended minimum. In series, voltages add up and the current stays that of one panel. Check these values on the label of each panel:

Power (Pmax) 500 to 550 Wp per panel
Maximum power voltage (Vmp) 30 to 40 V: in series, 90 to 120 V
Open-circuit voltage (Voc) 45 V maximum per panel: in series ≤ 135 V, about 149 V at −10 °C
Number of panels 3 in series, never more
Avoid large panels of 580 Wp and more (144 half-cells), whose open-circuit voltage is around 50–52 V. 3 in series would exceed 150 V in cold weather and damage the controller. For a very cold site, have the set-up checked.

Connecting the MPPT controller

Panels → P+ / P−

The PV array connects to the solar input P+ and P−, with correct polarity and suitable DC protection.

Motor → U / V / W

The three motor phase conductors connect to the U, V and W outputs of the controller.

Level sensors → dedicated inputs

Compatible probes can stop the pump when the source runs dry or the tank is full. Terminals and logic are checked in the manual.

Wiring diagram of 3 solar panels in series to the 90–120 V MPPT controller of the pump

Principle diagram, to be completed with the manual of the equipment supplied. Wire with the power off, by a qualified person, then check polarity and voltage before commissioning.

The full Flocea range of solar surface pumps

High-pressure models for low flows and high heads, centrifugal models for large flows: choose according to your needs.

Pump Max. flow Max. head Connections Panels
210 W solar pump – 2 m³/h 2 m³/h 25 m 1″ 1 × ~400 Wp
280 W solar pump – 2 m³/h 2 m³/h 30 m 1″ 1 × ~400 Wp
550 W solar pump – 3 m³/h 3 m³/h 50 m 1″ 2 × ~450 Wp
750 W solar pump – 3 m³/h 3 m³/h 65 m 1″ 3 × ~450 Wp
550 W solar pump – 6 m³/h 6 m³/h 30 m 1″ 2 × ~400 Wp
550 W solar pump – 18 m³/h 18 m³/h 14 m 2″ 2 × ~400 Wp
750 W solar pump – 21 m³/h 21 m³/h 14 m 2″ 3 × ~450 Wp
1,100 W solar pump – 26 m³/h (this page) 26 m³/h 15 m 2″ 3 × ~500 Wp
1,500 W solar pump – 27 m³/h 27 m³/h 21 m 2″ 4 × ~500 Wp
1,500 W solar pump – 55 m³/h 55 m³/h 17 m 3″ 4 × ~500 Wp

Preparing an installation that keeps the flow

  1. Place the pump on a stable, dry base, out of the water, protected from frost and as close to the source as possible.
  2. Plan a short, airtight and non-collapsible suction line, at least 2″, with a strainer and foot valve.
  3. Keep the strainer submerged and away from the bottom to limit debris intake.
  4. Fill the pump casing and suction line with water before each start from empty; never run the pump dry.
  5. Size the delivery line according to length and flow: a PE pipe of at least 63 mm for a few tens of metres, 75 to 90 mm for a longer line.
  6. Mount the controller in the shade, connect panels, pump and probes with a DC isolator, then check fittings and strainer regularly.

Your questions about this solar pump

Does the pump deliver 26 m³/h all the time?

No. 26 m³/h is a maximum flow, at very low head and in full sun. At 8 m head, expect about 15.8 m³/h. Head, friction losses and sunlight determine the actual flow.

Can it lift water from a deep well?

No. It is a surface pump: it only draws water up a few metres and must be placed close to the water level. The 15 m head is not a suction depth. For a well or borehole, choose a submersible pump.

Which solar panels should I choose?

3 identical panels of 500 to 550 Wp in series: Vmp 30 to 40 V and Voc of 45 V maximum each. Avoid panels of 580 Wp and more, whose open-circuit voltage is too high.

Does it work at night or in cloudy weather?

In direct solar mode it runs only when there is enough PV energy. Clouds reduce or interrupt the flow; at night, use the water stored in a reservoir.

What pipe diameter do I need?

The ports are 2 inches. For the delivery line, plan a PE pipe of at least 63 mm for a few tens of metres, 75 to 90 mm for a longer line. A pipe that is too small adds friction losses and reduces the flow.

Can it pump dirty water?

It is designed for clear water. A strainer is essential; sand, mud or fibres wear the impeller and can block the pump.

Are level sensors mandatory?

No, but they are recommended: they stop the pump when the source runs dry or the reservoir is full. Their connection is checked in the controller manual.

Let’s start from your water needs

Tell us the daily volume you need, the water level at the source, the elevation, the length and diameter of the pipes and the model of your panels: we check the right pump and set-up before you order.

Solar pump configurator